THE SMART TRICK OF ATS SOCOMEC THAT NO ONE IS DISCUSSING

The smart Trick of ATS Socomec That No One is Discussing

The smart Trick of ATS Socomec That No One is Discussing

Blog Article

Probability to established periodic genset startup Risk to established periodic genset startup ATyS p switches provide further features for servicing. They include things like a programmable genset starting function which permits the commencing dates and working times to be configured.

Electricity backup The built-in Electrical power backup provides transitional electrical power on the product or service enabling position indicator (swap posture, timer position, fault notifications) and interaction to stay Lively without having source existing for nearly thirty seconds.

Proof against voltage fluctuations The power source on the ATyS p M is just active all through transfer. As being the solution is predicated on steady positions, It isn't afflicted by network voltage fluctuations.

Safe ATyS p M have both of those electrical and mechanical interlocks for optimum safety. Additionally they feature a optimistic split indicator, confirming swap position with dual mechanical indicators for amplified safety.

Versatile programming ATyS p M time delays and inputs/outputs are totally configurable, hence enabling the simple monitoring of unique apps (load shedding, test…) as well as definition of an working cycle specifically tailored for your software.

ATyS C35 is an ATS controller by using a display screen and conversation operation. It really is precisely made to pilot Socomec remotely operated transfer switches, for instance ATyS r, ATyS S and ATyS dM, and can also operate with other models making use of switch based mostly, contactor dependent or circuit breaker based remote transfer switches.

Awesome Grid, storage for integrating renewable energy and islanding Paradise, a smart network to the area people Solenbat optimises the Energetic Strength effectiveness of structures Stem, Strength storage devices for minimized energy billing Innovation Shut

They are supposed to be used in very low voltage electricity offer methods where by a brief interruption on the load supply is acceptable all through transfer.

EN Useful resource this site library has every little thing you require to help you pick the most beneficial energy Remedy.

The ATyS g’s integrated controller continues to be designed to deliver unique features for these programs (genset startup, on-load or off-load tests…) along with the monitoring from the voltage and frequency of both resources for three-section and solitary-phase networks.The generator source need to be connected to swap II, Positioned on the rear.

The ATyS C66 can be an ATSE controller created to Command every type of unexpected emergency systems, legally expected and optional standby transfer switching gear as per NEC (NFPA 70).

Great Grid, storage for integrating renewable Power and islanding Paradise, a smart community for that area people Solenbat optimises the active Electrical power performance of structures Stem, Power storage systems for lessened electric power billing Innovation Near

Good Grid, storage for integrating renewable Electrical power and islanding Paradise, a wise network for that local community Solenbat optimises the Lively Vitality performance of structures Stem, energy storage devices for lowered energy billing Innovation Near

- All principal features for instance distant position Manage, method assortment, lamp take a look at and genset exam on load are available around the front in the product or service allowing for quick and easy operation.

Vacation function ATyS p M includes a operate for returning on the 0 situation in the event of the lack of both equally ability source resources (tripping). This guards the load from issues because of source instability.

Report this page